Description:
The volume booster amplifies the volume at a 1:1 ratio of pilot pressure to outlet pressure. The booster is robust, highly accurate and sensitive. The hysteresis between the outletpressure and the relievingpressure is very small and constant. Caused of the inlet pressure compensation of the control valve the regulator is stable against fluctuations in inlet pressure vibrations due to sudden changes of the volume flow are prevented by damping in the diaphragm chamber.
Media: compressed air or non-corrosive gases
Supply_pressure: max. 17 bar
Pilot_pressure: max. 10 bar
Accuracy: response sensitivity 15 mbar
Internal_air_consumption: no internal air consumption
Relieving_function: relieving, tapped exhaust function 3/4 NPT
Relief_capacity: 4245 l/min at 0.35 bar overpressure above setpoint
Gauge_port: 1/4 NPT on both sides of the body
Mounting_position: any
Temperature_range: -40 - 93 °C; optional -52 °C
Material: aluminium die-cast
Elastomer: NBR
Inner_valve: aluminium and galvanized steel