Choose a version from the table underneath, please.
        Description:
        Air supply is immediately shut off when volume flow exceeds a
 specific value. The maximum admissible flow is factory-set in
 such a way that a standard application of pneumatic equipment
 is ensured. Pressure drop amounts to 0.05 to 0.3 bar. In the
 case of failure, the hose rupture valve blows off through a small
 nozzle. After repairing the hose break, the hose rupture valve can
 be set to zero again.
 
 EN_ISO_4414-11.2010: According to EN ISO 4414-11.2010 the hose
 rupture valve protects individuals, systems and machines from injuries
 or damages caused by lashing hose lines in the event of hose breaks.
 
 Function: The air passes the piston and continues through the seat.
 The air stream is slowed down by means of lengthwise grooves on the
 piston surface. When the volume flow is too high, the air cannot pass
 the piston quickly enough, thus the piston will be pressed against the 
 spring. If the maximum admissible flow is exceeded, e.g. when the hose
 suddenly breaks, the air supply will automatically be shut off.
 
 Supply_pressure: max. 18 bar
 
 Temperature_range:
 -20 °C to 80 °C / -4 °F to 176 °F at G1/4 to G1/2,
 up to 120 °C / 248 °F at G3/4 to G2
 
 Body: aluminium, optionally stainless steel 
 Elastomer: NBR/Buna-N
 Inner_valve: aluminium and plastic
       
 
  

 
              



 
		            